WhatsApp: ; Email:
Work










The positive electrode (BP) is a platinum-rhodium alloy, which contains 30% rhodium and 70% platinum. The positive electrode is platinum-rhodium 30.
The negative electrode (BN) is a platinum-rhodium alloy with a rhodium content of 6%. The negative electrode is platinum-rhodium 6.
The positive electrode (BP) is a platinum-rhodium alloy, which contains 30% rhodium and 70% platinum. The positive electrode is platinum-rhodium 30.
The negative electrode (BN) is a platinum-rhodium alloy with a rhodium content of 6%. The negative electrode is platinum-rhodium 6.
Use environment:
1: Suitable for oxidizing and inert atmospheres, and also for short-term use in vacuum.
2: Not suitable for reducing atmosphere or atmosphere containing metal or non-metal vapor.
Advantages of B-type thermocouple:
1: Type B thermocouple does not need to use thermocouple compensation wire, because the thermoelectric potential is less than 3μV in the range of 0~50℃.
2: Has the highest accuracy in the thermocouple series
3: It has the best stability in the thermocouple series,
4: The measuring temperature range is very wide,
5: Long service life
6: The upper limit of the measurement temperature is relatively high
Measuring temperature range of type B thermocouple
1: Type B thermocouple can measure the temperature of the medium from 0 to 1800°C.
2: Type B thermocouple can be used for a long time at 1300~1600℃.
3: Type B thermocouple is the best thermocouple for high-temperature measurement.
| Thermocouple | Product modle | Length | Insertin Depth | Graduation | Thermometric | Specification |
| category | 300 | 150 | mark | scope | Diam(mm) | |
| single | GST01 | 350 | 200 | S/R/B | 0-2500C | Ф16 |
| Pt Rh30-Pt Rh6 | GST02 | 400 | 250 | Ф25 | ||
| Double | GST01 | 450 | 300 | Ф16 | ||
| Pt Rh30-Pt Rh6 | GST02 | 550 | 400 | Ф25 | ||
| Single Pt Rh10-Pt | GST01 | 650 | 500 | Ф16 | ||
| GST02 | 900 | 750 | Ф25 | |||
| Double Pt Rh10-Pt | GST01 | 1150 | 1000 | Ф16 | ||
| GST02 | 1250 | 1100 | Ф25 |