1700C Atmosphere Furnace

For any inquiry, please send to this email: sales@gensitherm.com

This is an atmosphere-controlled box furnace, which is designed for sintering materials under high purity oxygen. The furnace consists of high-quality alumina fiber bricks and MoSi2 heating elements with a heating chamber of 8″x 8″x8″. It is an ideal tool for preparing high purity oxide ceramic materials, especially for high Ni battery cathode materials.

This is an atmosphere-controlled box furnace, which is designed for sintering materials under high purity oxygen. The furnace consists of high-quality alumina fiber bricks and MoSi2 heating elements with a heating chamber of 8″x 8″x8″. It is an ideal tool for preparing high purity oxide ceramic materials, especially for high Ni battery cathode materials. The furnace also can be used under inert gases up to 1600oC.

 

SPECIFICATIONS

Furnace structure MoSi2 heating elements with Ni coated copper capable connection

Double-layer steel structure for maximum vacuum and safety.

Water cooling front door and air cooling shell

Built-in pressure gauge, vacuum valves, and two gas float meters

Power AC 208 – 240V single phase (50/ 60 Hz)

30 Amp (50 Amp air breaker is required)

7.5 KW

The power cable is included but no plug ( please inform us of your plug type, we can install for you upon request

Heating Elements 6 sets of MoSi2 heating elements are built-in and replaceable

Working temperature range: 1200oC – 1700oC in air or oxygen

Note: the heating elements also can be used under inert gas at 1000oC – 1600 oC)

The furnace is not a high vacuum furnace. The vacuum level is about 500 torr at high temperature

Temperature Continuous 300 – 1600°C

Max. 1700°C(<60min)

Accuracy: +/- 0.1°C

Heating Rate: 5°C / min

Thermocouple: two B type T/C for control and monitor alarm separately

Control Panel Built-in PC for controlling temperature and pressure

Temperature Control:

Eurotrem 3000 controllers inside for +/- 0.1oC accuracy connected to PC

24 segments programmable

Protection for over-temperature and current, as well as the thermal couple, broke

A secondary temperature controller is built-in for extra over-temperature protection.

Pressure Control:

The pressure sensor and pressure controller are installed to control the set pressure constant.

The pressure control can be used to perform the following functions:

Inert gas Purging via manually or an automatic mode

Constand pressure during heating

High and Low-pressure protection

The pressure controllable range: -0.06 to 0.03Mpa.

Safety Alarm System:

Over-temperature protection

Over-pressure and lower pressure alert

Low water flow alert

Data Collection

Recording temperature profile

Recording pressure profile

All data is saved to the hard disc of the PC

Vacuum pump & Gas Flow Control Two large flow meters are installed on the front panel of the furnace for purging via inert gas and filling oxygen gases

One vacuum pump is included to enhance purging and keep the chamber below 760 torr

Low vacuum 10-1 torr due to fibrous alumina insulation material. Using 5% H2 + Ar will improve oxidation during heating. For oxygen-sensitive material, please use a hydrogen furnace

Water Cooling A 58L/min recirculating water cooling is required to cool the furnace sealing flange and chamber case.